Re: Case 0400_05 -- Recurrent Pulmonary Embolus After IVC Filter Placement


Posted by Rob Kirsch on May 01, 2000 at 22:49:06:

In Reply to: Case 0400_05 -- Recurrent Pulmonary Embolus After IVC Filter Placement posted by Editor on April 04, 2000 at 17:01:44:

I use the brachial approach with a Simon-Nitinol filter whenever possible. It's even easier than the IJV approach (which is my next preferred approach), and is very well tolerated by the patient. I puncture either the median brachial or the cephalic vein (if the cephalic is big enough).

I agree that this patient needs a hypercoaguability evaluation.